Data sheet

Pocan B3235LT 904040


PBT, 30 % glass fibers, injection molding, improved laser-transparency, NIR-laser transparent coloring (black)
ISO Shortname:ISO 20028-PBT,GF30,GHMR,09-100
Property Test Condition Unit Standard guide value
Rheological properties
C Melt volume-flow rate 270 °C; 2.16 kg cm³/(10 min) ISO 1133-1 20
C Molding shrinkage, parallel 60x60x2 % ISO 294-4 0.3
C Molding shrinkage, transverse 60x60x2 % ISO 294-4 0.8
Post- shrinkage, parallel 60x60x2 % ISO 294-4 0.05
Post- shrinkage, transverse 60x60x2 % ISO 294-4 0.2

Mechanical properties (23 °C/50 % r. h.)
C Tensile modulus 1 mm/min MPa ISO 527-1,-2 10000
C Tensile Stress at break 5 mm/min MPa ISO 527-1,-2 140
C Tensile Strain at break 5 mm/min % ISO 527-1,-2 2.8
C Charpy impact strength 23 °C kJ/m² ISO 179-1eU 62
Izod impact strength 23 °C kJ/m² ISO 180-1U 54
Flexural modulus 2 mm/min MPa ISO 178-A 9500
Flexural strength 2 mm/min MPa ISO 178-A 225
Flexural strain at flexural strength 2 mm/min % ISO 178-A 3.2

Thermal properties
C 熔化温度 10 °C/min °C ISO 11357-1,-3 225
C Temperature of deflection under load 1.80 MPa °C ISO 75-1,-2 195
C Temperature of deflection under load 0.45 MPa °C ISO 75-1,-2 215
C 系数线性热expansion, parallel 23 to 55 °C 10-4/K ISO 11359-1,-2 1.0
C 系数线性热expansion, transverse 23 to 55 °C 10-4/K ISO 11359-1,-2 0.2
C Vicat softening temperature 50 N; 50 °C/h °C ISO 306 200

Electrical properties (23 °C/50 % r. h.)
C Comparative tracking index CTI Solution A Rating IEC 60112 300

Other properties (23 °C)
C Density kg/m³ ISO 1183 1520
Bulk density kg/m³ ISO 60 700

Processing conditions for test specimens
C Injection molding-Melt temperature °C ISO 294 260
C Injection molding-Mold temperature °C ISO 294 80

Processing recommendations
Drying temperature circulating air dryer °C - 120
Drying time circulating air dryer h - 4-8
Residual moisture content % Acc. to Karl Fischer 0.00-0.02
Melt temperature (Tmin - Tmax) °C - 250-270
Mold temperature °C - 80-100
C These property characteristics are taken from the CAMPUS plastics data bank and are based on the international catalogue of basic data for plastics according to ISO 10350.
Disclaimer
Disclaimer for commercial products
This information and our technical advice - whether verbal, in writing or by way of trials - are given in good faith but without warranty, and this also applies where proprietary rights of third parties are involved. Our advice does not release you from the obligation to verify the information currently provided - especially that contained in our safety data and technical information sheets - and to test our products as to their suitability for the intended processes and uses. The application, use and processing of our products and the products manufactured by you on the basis of our technical advice are beyond our control and, therefore, entirely your own responsibility. Our products are sold in accordance with the current version of our General Conditions of Sale and Delivery.
Test values
Unless specified to the contrary, the values given have been established on standardized test specimens at room temperature. The figures should be regarded as guide values only and not as binding minimum values. Kindly note that, under certain conditions, the properties can be affected to a considerable extent by the design of the mould/die, the processing conditions and the coloring.
Processing note
Under the recommended processing conditions small quantities of decomposition product may be given off during processing. To preclude any risk to the health and well-being of the machine operatives, tolerance limits for the work environment must be ensured by the provision of efficient exhaust ventilation and fresh air at the workplace in accordance with the Safety Data Sheet. In order to prevent the partial decomposition of the polymer and the generation of volatile decomposition products, the prescribed processing temperatures should not be substantially exceeded. Since excessively high temperatures are generally the result of operator error or defects in the heating system, special care and controls are essential in these areas.
LANXESSDEUTSCHLAND GMBH|D-50569 COLOGNE
Date: 2018-11-21 05:25:55.0